HVAC troubleshooting: what to check before you call anyone
Eleven symptoms cover most of the calls a heating and cooling company gets: four for cooling, seven for heating and hot water. Each one below names what usually causes it, the checks that are genuinely safe to run yourself, and the point where a licensed technician takes over.
Still down? Price the fix in your ZIP, free →Start with the symptom you actually have
Warm air with the fan running is the most common cooling call, and the outdoor unit is usually where the answer is. If the condenser fan isn't spinning or the compressor is silent, nothing is being cooled no matter what the thermostat says. A humming outdoor unit with a still fan points at a failed capacitor — a cheap part, but one that strains the compressor every time it tries to start. A thermostat fan set to On instead of Auto will also move air all day without cooling it.
- 01Thermostat in Cool, setpoint below room temperature, fan on Auto
- 02The outdoor unit actually running — fan spinning and compressor humming
- 03Two feet of clear space around the condenser, and a clean filter inside
If the outdoor unit hums but the fan won't spin, turn cooling off and call — running it that way can burn out the compressor.
Check the outdoor unit first, every time.
Ice on the copper lines or the indoor coil means the coil is running colder than it should. The usual cause is too little air across it — a clogged filter, a dirty coil, or closed registers — and the next most common is a low refrigerant charge from a leak. Iced-up equipment cools less and less until it stops, and the meltwater can overflow the drain pan when it thaws.
- 01Switch cooling off and run the fan only until the ice is gone
- 02Replace the filter, or wash a mini-split's indoor filters
- 03Open every supply register and clear the return grilles
If it ices again with a clean filter and full airflow, it is almost always a refrigerant leak — that needs a licensed technician to find and repair.
Ice is an airflow or refrigerant problem, never a thermostat one.
An air conditioner pulls gallons of water out of the air on a humid day, and all of it has to leave through one small drain line. When that line clogs with algae, the pan overflows — onto the ceiling below an attic unit, down the wall under a mini-split, or across the closet floor. Many systems have a float switch that shuts cooling off when the pan fills, so a leak and an AC that stopped cooling are often the same problem.
- 01Turn cooling off to stop more water forming
- 02Look for a full secondary pan or a tripped float switch near the indoor unit
- 03Find where the drain line ends outside and see whether it is dripping
Water near wiring or a ceiling that is sagging is a stop-now situation: shut the system off at the breaker and call.
Most indoor leaks are a clogged condensate drain.
Short cycling — starting, running a few minutes, then shutting off — wears out a compressor faster than anything else. The causes range from simple to serious: a thermostat mounted in a sunny spot or over a supply vent, a clogged filter tripping a safety, a unit that is oversized for the house, or a high-pressure switch tripping on a dirty outdoor coil or a refrigerant problem.
- 01Where the thermostat is — direct sun, a lamp or a supply vent fools it
- 02The filter, and the outdoor coil free of grass, cottonwood and debris
- 03How long each run lasts, timed with a phone
If the outdoor unit itself is starting and stopping, have a technician check pressures and the safety switches before the compressor takes the damage.
Time the run: under five minutes is short cycling.
No fan, no click, nothing. Before you assume the furnace is dead, check what is asking it to run. A thermostat still in cool mode, a bumped service switch on the side of the cabinet, a breaker that tripped, or a blower door that didn't click back into place all leave a good furnace silent. After three failed ignition attempts most control boards lock out for an hour, and the board's blinking light is the fastest read you will get: the code legend is printed inside the blower door.
- 01Thermostat in Heat, setpoint above room temperature, batteries good
- 02The breaker, the service switch on the cabinet, and both panels fully seated
- 03The blink pattern on the control board, noted before you touch anything
If the fault light returns to the same code after one power reset, stop resetting it and call a licensed technician.
Most common: thermostat not in Heat, or a tripped service switch.
Full furnace guide →The burner lights, runs a few seconds, then drops out. That pattern usually points at the safety circuit rather than the flame: a flame sensor coated in oxide stops proving flame, an inducer that can't build enough draft trips the pressure switch, or a flue and intake plugged by ice or a nest does the same. A full condensate trap will shut a high-efficiency furnace down too, often on the first really cold day of the year.
- 01Clear ice, leaves or nests from the two white pipes outside
- 02Empty the condensate trap if the furnace has one
- 03A fresh filter, and every supply register open
Never bypass a pressure switch or tie a sensor back to keep the burner lit — both exist to stop unburned gas collecting in the cabinet.
Nine times in ten it is the flame sensor.
Full furnace guide →A blower running while the air stays cold is usually the furnace protecting itself. The high-limit switch opens when the cabinet gets too hot — most often a filter nobody has changed — and the board runs the blower to cool things down. The same symptom shows up when no flame arrives at all: a cracked hot-surface igniter, a gas valve that never opens, or a shutoff handle left across the pipe. If the water heater and range are out too, the problem is the gas supply.
- 01Filter condition, and every return grille clear of furniture or rugs
- 02The gas shutoff handle — parallel to the pipe means open
- 03Whether the igniter glows through the sight glass, without opening anything
If you smell gas, leave the house and call your gas utility. Do not relight a pilot or open the burner compartment yourself.
Cold air from the vents is usually a limit trip or a failed igniter.
Full furnace guide →Frost on the outdoor coil in cold, damp weather is normal: a heat pump stops every 30 to 90 minutes to defrost, and you may see a cloud of steam and hear a whoosh as it switches. Ice that keeps building into a solid block is not normal. It means the defrost control, its sensor or the outdoor fan has failed, or snow and roof runoff are burying the unit. A buried or frozen unit stops heating, and backup heat takes over at a much higher running cost.
- 01Watch for an hour and a half: frost that clears on its own is normal defrost
- 02Clear snow from around and on top of the unit, and keep roof runoff off it
- 03If it stays a block of ice, set the thermostat to Emergency Heat and book a technician
Never chip or pry ice off the coil or pour boiling water on it: the fins and tubing are thin and a puncture becomes a refrigerant leak.
Frost that clears is normal; a solid block of ice is a repair.
On the coldest nights a heat pump gets help from electric backup heat, and the thermostat shows 'Aux'. That is normal for short stretches. If 'Aux' is on most of the day in mild weather, the house only warms slowly, or the electric bill jumps far past last year's, the heat pump has probably stopped and the backup strips are doing all the heating. Emergency Heat is the switch you choose on purpose while the heat pump waits for a repair.
- 01Note when 'Aux' comes on and the outdoor temperature at the time
- 02Check the outdoor unit runs (fan turning) while the thermostat calls for heat
- 03Compare this month's usage with the same month last year on your utility bill
If the outdoor unit doesn't run in heat mode at all, a technician needs to check the outdoor unit's controls and refrigerant circuit.
Aux all day in mild weather usually means the heat pump has stopped.
A high-efficiency furnace makes water as it runs and drains it through a small line, often to the outside or through an attic. In a hard freeze that line can freeze and the furnace shuts itself off, usually with a pressure-switch code. The white plastic intake and exhaust pipes outside can also be blocked by snow, ice or drifting. Both are common on the first truly cold night of the year, and both stop a furnace that is otherwise fine.
- 01Clear snow and ice from the two white pipes where they leave the house
- 02Look for a frozen or kinked drain line, and a full condensate trap or pump
- 03Note the fault code before resetting, and reset only once
If the drain runs through a cold attic, a technician can reroute or heat-trace it so it doesn't freeze again.
A frozen drain line stops a good furnace.
On a gas tank, no hot water is usually the pilot or the thermocouple that proves it; a strong cold draft or a freeze can put the pilot out. On an electric tank it is usually a heating element or its thermostat, often with a tripped breaker. Cold weather also makes a tank work harder, so lukewarm water in winter can be an element that was already failing. Water around the base means the tank itself is leaking, and that is a replacement.
- 01Gas: look through the window for the pilot; relight only by the label's steps, and never if you smell gas
- 02Electric: check the water heater's breaker
- 03Photograph the tank's label: past 10 to 12 years, replacing usually beats repairing
Water pooling under the tank, or a relief valve that keeps discharging, needs a licensed plumber.
Pilot or thermocouple on gas, element on electric.
Where troubleshooting stops
If you smell gas, hear a boom, see soot or a scorched panel, or the furnace trips a limit switch twice with a clean filter — stop and call a licensed technician or your gas utility. Leave the building if you smell gas. Refrigerant, gas piping and anything inside a live electrical panel are not owner-serviceable, whatever a video suggests.
Photograph the nameplate/data tag before you call
Brand, model, serial and capacity are what every technician quotes from, and they decide whether a part is even still made. One photo of the data plate puts the unit on record, and HVAC Scout reads the specs, the age and the likely causes from there.
Start with a scanHow HVAC Scout reads a heating fault
What the app does with a furnace photo and a symptom, and where its diagnosis stops.
How does HVAC Scout diagnose a heating problem?
From a nameplate photo plus what the system is doing. It works through the heat sequence — thermostat call, filter and airflow, pressure switch, igniter, flame sensor, limit switches — and returns the causes ranked, naming the checks an owner can safely run, one at a time.
Can an AI app diagnose a furnace before a technician arrives?
HVAC Scout can narrow the fault and often name it: the model and serial establish the age and the known failure points, and the symptom and blink code match against them. That is information, not a diagnosis of record — gas, venting and the heat exchanger stay with a licensed technician.
HVAC Scout, on a heating fault
Photograph the nameplate, describe what the system is doing, and the Scout Report ranks the likely causes, names the checks you can run yourself, and prices the repair against a replacement.
- Covers the common faultsIgnition, flame sensor, pressure switch, inducer, high-limit and thermostat faults, plus the fault code.
- Prices it two waysParts and labor hours at local rates, next to the installed cost of a new unit.
- Warranty and parts checkedWhether the manufacturer still covers the part, and whether it is available nearby.
- No gas work, everIt never tells you to open a gas valve, bypass a safety switch or test a heat exchanger yourself.
- No gauges neededIt reads from the label and the symptom, not from manifold or combustion readings.
- Not an emergency serviceSmell gas or see a crack, and it says call a professional and stops there.
- Price
- $4.99 one Scout Report · $6.99 a month for a home ($64 a year), $15.99 a month for property managers and pros ($149 a year)
- Where
- Any browser, United States; prices in USD.
Questions owners ask here
Why is my furnace running but blowing cold air?
Usually a restricted filter or closed registers pushing the high-limit switch open, so the blower runs to cool the cabinet while the burners stay off. A failed igniter produces the same cold-air symptom. Change the filter, open the registers, and note the fault light before calling anyone.
How many times should I reset my furnace?
Once. If it locks out again after a single reset at the breaker or the board, stop — repeated resets on a fuel-burning appliance can hide a venting or gas problem that a technician needs to see.
What does the blinking light on my furnace mean?
It is a fault code. The legend is printed on the inside of the blower door on almost every residential furnace: count the blinks, note any pause pattern, and compare it to that sticker. The same code tells a technician where to start.
Can I check the gas valve myself?
Only the handle. A handle parallel to the pipe is open, across the pipe is closed. Anything past that — testing voltage at the valve, opening the burner compartment, relighting a pilot — belongs to a licensed technician.
Why isn't my AC cooling when the fan runs?
Most often the outdoor unit isn't running at all, the thermostat fan is set to On rather than Auto, or the filter and coil are loaded with dust. If the outdoor fan and compressor are both running and the air is still warm, the system is likely low on refrigerant from a leak.
How do I find my model and serial number for a technician?
It is on the data plate — a metal or printed label on the cabinet, usually on the outer panel or inside the blower door. Photograph it rather than copying the digits by hand; HVAC Scout reads the brand, model, capacity and age straight from the photo.